• ade accenta lcd remote keypad 8ep416 manual

    ade accenta lcd remote keypad 8ep416 manual

    Download Link: ➡ ade accenta lcd remote keypad 8ep416 manual



    File Name: ade accenta lcd remote keypad 8ep416 manual.pdf
    Size: 4774 KB
    Type: PDF, ePub, eBook
    Category: Book
    Uploaded: 17 May 2019, 16:44 PM
    Rating: 4.6/5 from 748 votes.


    Last checked: 8 Minutes ago!









    ⬆ LINK ⬆




















    In order to read or download ade accenta lcd remote keypad 8ep416 manual ebook, you need to create a FREE account.

    eBook includes PDF, ePub and Kindle version



    ✔ Register a free 1 month Trial Account.
    ✔ Download as many books as you like (Personal use)
    ✔ Cancel the membership at any time if not satisfied.
    ✔ Join Over 80000 Happy Readers


    Book Descriptions:

    ade accenta lcd remote keypad 8ep416 manual

    Before entering Engineer program mode the system should be unset, with the and indicators lit. This function tests all the outputs on the system.Pressing the leaves the function.LED’s 1 and 2 are on. LED’s 1and 2 are on. Up to 250 events can be stored in the memory. When the log reaches 250 events and another event takes place, the first event drops out. Flashing LED indicates the first zone in alarm.LED’s 1 and 2 are on. LED 2 is on. To assign a zone as immediate, remove the timed or timed inhibit function and make sure that it is enabled in the Used Zones section. The programmable range is 00-99 seconds. The actual time is multiplied by 10. If the Exit Time is interrupted within the last 10 seconds, then the Exit Time will restart at 10 seconds after the interruption has cleared. Program 1 cannot be disabled. For further information please refer to the Gen 4 Series User Guide. The LED is ON and the LED is OFF indicating that the system is set. Engineer Restore If the system has to be set by an engineer the message Required Engineer Restore Required is displayed. Whenever working close to the mains supply or connector, you should exercise extreme caution. Always isolate the mains supply before removing the control panel covers. The Optima version has the keypad and indicators on the main control panel. The Accenta version has the keypad and indicators on a small remote LCD or LED keypad. You operate the alarm system by pressing keys on the keypad and viewing the indicators. Both alarm systems work the same way. NOTE: The Accenta Remote LED keypad is not shown. It will have the same indications as the Optima compact panel with built-in keypad. Part set operation is often used at night time, and it permits you to freely walk around the bedrooms while the living area and outside doors are protected. The exit tone stops and the zone LED’s 1to 3 come on.

    • ade accenta lcd remote keypad 8ep416 manual, ade accenta lcd remote keypad 8ep416 manual download, ade accenta lcd remote keypad 8ep416 manual pdf, ade accenta lcd remote keypad 8ep416 manual free, ade accenta lcd remote keypad 8ep416 manual instructions.

    Features 8 zones programmable for Security, 2 zones for Fire. PA input. Tamper input. Outputs for External Siren (Bell) and Strobe. The Accenta panel may be concealed inside a cupboard or loft space, but it must be installed within the protected premises and in a position which is convenient for a mains supply. NOTE: The Accenta Mini enclosure is illustrated here, however the procedures for the other panels is similar. Remove the front cover(s) from the base assembly. Up to four remote LCD or LED keypads can be connected to the panel. Wire the keypad(s) as per Figure 5 (LED keypad) or Figure 6 (LCD keypad). Cut away the required thin wall sections around the edges of the baseplate for cable entry. The baseplate may be fitted directly to the wall using screws and wall plugs. If these are not appropriate for the wall then use suitable alternative fixings. This will automatically exclude the availability of the zone from programs and normal security applications.Operational in Unset and Set, the PA circuit will cause a full alarm condition when activated. PA is indicated on the control panel or RKP. Terminal TADB are for connection to the external siren.Twin External Siren Wiring 13V Supply Output The 13V output is to power detectors which require a voltage supply (PIR detectors etc). The supply is present at all times and may be used to supply a total load of 350mA. These terminals have been provided for connection to remote signalling equipment such as a digital communi- cator, or speech dialler. Where the communicator is powered from an external source, not the panel and the outputs are being used without relays, the panel and external power supply will require a common negative supply rail. The 2 A fused spur must be located close to the control panel. Check that the factory fitted links are connected to terminals PA, TAMP and T-A. Once the Engineer program mode has been accessed, each configuration may be changed in any order.

    Accept Cookies Customise Cookies Please try your search again later.You can edit your question or post anyway.The only issue that I had was that my original keypad had words on the buttons (Reset, Omit, etc.) and this one has symbols, so you will need to create a crib otherwise the manual for the alarm doesn't make sense. Then you can remove the RKP (note where the cables belong!).Then you can remove the RKP (note where the cables belong!).Then you can remove the RKP (note where the cables belong!).Suggest you contact manufacturer first. It is the only way you can do it. Be aware that you will have to reprogram your alarm from scratch.It is the only way you can do it. Be aware that you will have to reprogram your alarm from scratch. You require 6 core alarm cable. Set the panel into engineer mode and remove the front of the panel and the terminals are marked. If you do not have experience, don't do it.You require 6 core alarm cable. If you do not have experience, don't do it. By all means lay the cable and contact an alarm engineer to connect up for you.You require 6 core alarm cable. By all means lay the cable and contact an alarm engineer to connect up for you. It should work if these match. Will this keypad work?No idea what type of alarm system we have Can you not just get the same pad as you already have thats what we did. Something went wrong. Packaging should be the same as what is found in a retail store, unless the item is handmade or was packaged by the manufacturer in non-retail packaging, such as an unprinted box or plastic bag. Stylish and discreet Honeywell Keypad for Accenta and Optima Gen3 and Gen4 Alarm panels. Can be mixed with Accenta LCD keypad. Full LED status indication. Worked as a direct replacement for the old tired keypad on my G3 system. It had been working fine for more than 20 yrs so no complaint. Bought as replacement for previous same model, which had simply worn-out after about 10 years use.

    It is particularly useful in a shop to warn of customers presence, or in a house to warn when a back door has been opened.All codes are 4-digits. User code 1 can only be changed by user 1. You may find it useful to set up user code 2 for use by a neighbour for use when you are on holiday. User code 2 operates like user code 1, but it cannot be used to change or delete user code 1. The Duress code is used in a hold-up situation where there is pressure to set or unset the system. The Duress code operates like your normal code but in addition it silently sends a signal to the Alarm Receiving Centre. The events are arranged by date and time. Zone, LEDs are on, to show zone in alarm. A flashing LED indicates the first zone in alarm.The LED goes off to indicate that you are in Programming mode.Also, open and close all door and windows that are protected by the system. For each detector (including door or window sensor) that is activated the system produces a series of beeps, and the associated zone is indicated on the keypad. The goes off, indicating that you are in Programming mode. Lampholders You can install up to 4 keypads per control panel. Download product manual (368.48KB) Both in the showroom and online you can find a wide range of electrical items, heating solutions, fire alarms, security systems, switches and sockets, and many other devices to meet all your electrical needs. Thank you for visiting our website. You must have JavaScript enabled in your browser to utilize the functionality of this website. The LED remote keypad feature entry and exit tones for your peace of mind. Apart from the terminals on the PCB being on the opposite side to the old keypad this is an excellent item. I paid slightly more to get the exact replacement item (as shown on the web site), but received a slightly modified product. Approved third parties also use these tools in connection with our display of ads. Sorry, there was a problem saving your cookie preferences. Try again.

    The local authority requirements may differ from area to area, therefore, it is advisable to contact local environmental officer to obtain full details of your area requirements. 2. NOTE: The Accenta mini enclosure is illustrated here, however the procedures for the other panels is similar. S Q 1. Remove the front cover(s) from the base assembly. R Figure 1. Removing the Front Cover R S 2. Disconnect the transformer wires from the board, these are marked AC. Carefully remove the board by gently pushing down the holding clips on the bottom edge of the board and withdraw it from the base. Q NOTE: When replacing the board align it on the round support pillars to the bottom and allow it to click down past the clips at the top of the case. Refit the transformer wires into the terminal. Figure 2. Removing the PCB Mounting holes Note: For Mains supply cable use Flat Twin and Earth 1mm 2 3. Fit the panel to the wall with suitable fixings. Ensure the wall surface is flat to prevent base distortion. There are cable entry holes provided in the rear of the base and around the outside edges through the thinned out plastic sections which may be cut away as required. FUSE T125mA 250V (ANTI-SURGE) Figure 3. Fitting the Panel 3. Tamper Network The Tamper circuit is used to protect all cables and detectors in the system from unauthorised access including the panel and RKP covers. The zone and PA tampers should be series wired and connected to the TAMP terminals. Terminals T and A are for the external siren tamper. The TAMP terminals at the bottom left of the board are for the RKP tampers. Tamper alarms that occur in the Day mode operate internal sounders only. Tamper alarms in Set cause a full alarm condition. Tamper is indicated on the control panel and RKPs. 4. Up to four remote Accenta LCD or LED keypads can be connected to the panel. Wire the keypad(s) as per Figure 5 (LED keypad) or Figure 6 (LCD keypad).

    Well made, easy to use, neat appearance, easy to install, good price. Purchased this to replace an older system. I found this to be a far superior system. I fitted this in approx. 15mins. Easy. No problems. Highly recommended. Excellent service and quality. Cancel Thanks, we'll look into this. All Rights Reserved. User Agreement, Privacy, Cookies and AdChoice Norton Secured - powered by Verisign. Programmable timers including bell cut off. Walk Test facilities. Quick set feature. Supports up to four remote keypads with on board PA and illuminated keys positioned up to 100 meters from the panel. Keypads can be wired in a star or daisy chain configuration from the panel. Optima is supplied with a built in keypad. Support of Prox set and unset with Simple Set keypad. NVM for protection of engineer program and event log. 5 digital outputs for a wire-in digital communicator or dialler (Not applicable for Optima compact panel). It is important to plan the installation before proceeding following the procedures and advice contained in this manual. Plan the position of each part of the alarm system and the cable runs. Detectors should be sited with particular regard to the degree of coverage required. All of the system wiring is connected directly to the panel. The Accenta panel may be concealed inside a cupboard or loft space, but it must be installed within the protected premises and in a position which is convenient for a mains supply. This will enable the system operator to check that the system is setting correctly. The total current output of this control system (in alarm condition) is 1A when supported by a fully charged battery. Calculate the total including the panel, remote keypads, external siren with strobe light (also called a bell box) and detectors to ensure that this rating is not exceeded. Depending on which area you live, you may be required, by law to notify the Local Authority and Police of the new security alarm installation.

    NOTE: The mains supply must be connected by a technically competent person and according to current IEE regulations. Mains Connection CAUTION: To avoid the risk of electrical shock you must always totally isolate the mains supply before opening the control panel cover(s). Mains Input fuse rating: 125 ma, 250 V type T (anti-surge) and of a type approved to IEC 127 part 2 sheet III. On connecting the mains supply to the panel the power indicator is lit. Power Testing the System Complete the wiring of the system and then: Fully test the system and ensure it is fault free. Fully program the system. Fill in the installation log at the back of the manual and retain if for future reference. Finally explain the operation of the system to the end user. The User Guide is attached to the centre of this manual. Detach the User Guide and leave it with the user. 14. Battery Connection 3 On connecting the battery, the system will go into an alarm condition with an audible alarm indication. After entry of a valid user code, there is a Tamper indication. 4 Fit the cover to hold down the tamper spring at the bottom centre of the board. The alarm condition will cease and the system will go into day mode: NOTE: The LCD keypad will show SYSTEM UNSET for 30 seconds first. Once the Engineer program mode has been accessed, each configuration may be changed in any order. Before entering Engineer program mode the system should be in the Day mode, with the Day and Power indicators lit. Indications on LED Keypads LED Indications LED steady on indication LED flashing indication LED off Output to Alarm Receiving Centre Communicator outputs are not applicable for Optima compact panel ARC Internal Sound. In general a flat beep is an indication of an incorrect key press External Device: Strobe External Device: Siren Table 1.

    LED Indications To exit operation RESET Quit the current function Leave program menu Return one menu level System Indications LCD Indications LED Indications System Unset System Unset indication System Set System Set indication 16. To default to factory settings: 1. Power down panel. 2. Remove wiring from SET output and PA input. 3. Fit shorting wire between SET and left-hand PA terminal. 4. Power up. 5. Wait for alarm to start. 6. Power down panel and then restore original wiring. A tone is generated as each zone is activated (opened). Zones 1-8 have a zero (0) below each number. When a zone is sucsessfully tested, number 1 replaces the 0. Zones are added to list as each one is activated. Zones are added to list as each one is activated. The Tamper LED comes on when tested. To test for a high volume sounder enable both options 2 and 3 together. This function tests all the outputs on the system. When the flag is set to OFF the system can be reset by the user. The user can reset the system even if the Engineer Reset flag is set to ON. A code entry is not required. However, a 4-digit code is required to Unset the panel. Strobe on Set When this flag is set to ON, the external strobe will stay on for five seconds once the panel has set. Flag 3 Flag 3 shows the Software Version of the panel and may be requested when contacting technical support. Use the up arrow to scroll through the screens. LCD keypad only: Example information you may see: System and software version Part No for software English Version Build Build Accenta Optima Version 1.00 F Build 101 (01)R Date May View more Unset system indications. Set System indication Programs 1, 2 and 3. Access codes. How to operate Personal Attack SYSTEM OPEN 17:30 01 Jan ENT 0 ESC The Active 5 is a microprocessor controlled intruder alarm panel.

    NOTE: When the panel back-up battery is charging, the LCD keypad backlight may not operate. 5. As an alternative, the baseplate may be fitted directly to the wall using screws and wall plugs. If these are not appropriate for the wall then use suitable alternative fixings. CAUTION: The PCB board must not be removed from the front moulding and doing so may invalidate the warranty. 4 Bring the cables into the baseplate and wire to the terminal block on the baseplate. 5 Refit the RKP main assembly to the baseplate by locating the top retaining clips into the inside top part of the baseplate. Resecure the screw in the bottom of the case. Security Zones It is recommended that no more than 10 magnetic contacts are connected to the same zone and that the combined cable length for each zone does not exceed 100 metres. This will automatically exclude the availability of the zone from programs and normal security applications. A fire will cause a distinctive internal sounder tone. The external sounders will pulse on and off at 2 second intervals and all RKP indicators will flash the affected zone. 7. Operational in Unset and Set, the PA circuit will cause a full alarm condition when activated. PA is indicated on the control panel or RKP. PA buttons may be fitted near the front door or in a bedroom. Extension Speaker Wiring Up to two 16 ohm extension speakers may be wired across the speaker terminals. Mounted in convenient positions within the installation the extension speakers will reproduce all of the alarm tones generated by the control panel. Terminal TADB are for connection to the external siren. Where a discrete external siren is used, it should be connected to terminals D and B. Terminals T and A are then used for tamper protection for the housing. 9. Twin External Bell-box Wiring The 13V output is to power detectors which require a voltage supply (PIR detectors etc). The supply is present at all times and may be used to supply a total load of 350mA.

    Set The output marked SET is used with latching detectors. The output becomes positive on correct Set of the system and is removed by entry of a valid user code. 10. These terminals have been provided for connection to remote signalling equipment such as a digital communicator, or speech dialler. 13V 0V: These terminals provide a 13V supply for the communicator up to a total load of 200mA. OUTPUTS (J3): These outputs are programmed as active low output. They are held at 13V and fall to 0V when active, it can source or sink 10mA. These outputs would normally be connected directly to the input channels of wire in type communicators. The relay will energise when the output port operates. Panel communicator FIRE: The fire output operates when the fire zone is triggered. PA: The PA output operates when a PA alarm is triggered or a duress code is used. INT: The intruder output is operated when an intruder condition is triggered whilst the system is set. SET: The Set output operates whenever the system becomes set and is used to indicate opening and closing. ABORT: Operates if the panel is unset within 90 seconds of the alarm condition starting. It is cleared when the panel is reset by the user or engineer. 11. In general, the panels offer the following methods that could be used to filter an alarm. Abort Output The abort output operates whenever a user code is entered to switch off an intruder alarm condition. When an abort signal is received by ARC at or around the same time as an intruder signal, the alarm can be filtered. Restore of the Intruder Output The intruder alarm output is restored to 12V whenever a user code is entered to switch off an intruder alarm condition. Where an intruder alarm is shortly followed by a restore at the ARC, this can be used to filter the alarm. 12. Zones Security zones Zones 1-8 Standard Fire zones None programmed Double Knock zones None programmed 13 The 2 A fused spur must be located close to the control panel.

    It features Installation and User Manual An intruder alarm system monitors and detects unauthorised entry to properties homes and businesses alike - The Informa uses ARMED Light is on when armed; off when disarmed; flashes to indicate a previous The Informa Default codes: User code: 1234 Master Manager Code: 2222 On every system s arming the counter is cleared in self. 6.3.11. 2 - Triger Timer - enter a The DESTINY has been designed to provide you with a maximum level of security PIMA Electronic Systems Ltd. www.pima-alarms.com MAINS CLEAR 24Hr. Zone 1 Zone 2 Zone 3 Zone 4 Follow the instructions in the proceeding Programmable 9 x 32 digit phone numbers for each trigger. 10 second Operating Guide. Proudly Designed and Manufactured in New Zealand We are committed to giving you the best home security available today All rights are reserved.you may download To use this website, you must agree to our Privacy Policy, including cookie policy. The Casil range by Honeywell is the range we recommend for all the panels we sell. The 2.1ah or 1.2ah will fit this panel. It features full and part set abilities and can take upto 8 zones, with two of them being allocated a fire zone if needed. This particular panel 8SP399A comes with LCD keypad and has a battery capacity upto 2.1ah. Please Sign in or create an account. If you would like to leave a review, simply press the 'write a review' button below Please ensure the length of the field is between 0 and 255. Easy to oper. Compact and economic polycarbonate LE. With the DUAL TEC DT8012F5, optimum performance is achieved using custom developed extended range Fresnel optics, look down, cover and wall tamper, and selectable pet immunity. The LED remote keypad feature entry and exit tones for your peace of mind. Replacement for 'Honeywell Activ8 Pet Immunity PIR Detector' Unit 1, Maritime Business Park. Dock Road. Birkenhead. Wirral.

    I would have no problem recommending them to others Add to Cart More Info Add to Cart More Info Add to Cart More Info Add to Cart More Info Add to Cart More Info. Scantronic 9751 with Keypad No longer available to buy as new. Installation and servicing are now even quicker. Operation is easier and more intuitive. Programming has been both simplified and extended. Make the right choice - the Veritas R8 Plus. Fully programmable and incorporating all the features that have made the Veritas R8 Plus the uncontested market leader, the Veritas Excel boasts a fully featured LCD remote keypad. Banner Text, User and Zone Names are all programmable and the 250 Event Log may be accessed directly. An intuitive menu system makes reference to the instructions unnecessary so programming is as easy as ABC. Up to 4 keypads per system the keypad has fully programmable zones and a 16 event memory log. Each zone operates in any of the 8 different zone types ensuring exceptional system flexibility. With ergonomically designed touchtone backlit keys, the Veritas RKP provides a superior user-interface. Easy to set-up and install, a hinged PCB chassis ensures excellent cable access and simple wiring. The Veritas R8 utilises the same intuitive universal programming platform as the rest of the Veritas Series, ensuring instant product familiarity across the range Category: Alarm Systems Condition: New Location: Stafford, United Kingdom Feedback: 7163 (99.3%) Type: alarm panel Features: Keypad Control MPN: CFA-0001 Brand: Texecom Number of Zones: 8 Items Included: Alarm Number of Cameras Included: 8 TEXECOM VERITAS 8 CONTROL PANEL CFA-0001The Texecom Veritas 8 has been upgraded with a host of new features. Installation and servicing are now even faster. Operation is quicker and easier. The Accenta mini G4 has 3 part set programsAllows three programmed setting levels dependent on the people in the property or the level of protection required, eg.Ideal for young, elderly or infirm.

    Personal attack facilityPA buttons may be used to activate the system in an emergency. An additional PA facility exists on the remote keypads. Remote keypads for added flexibility Up to four slimline keypads can operate the system from any point in the property. 5 Digi-OutputsFor a wire-in digital communicator, RedCare STU or Dialler. This allows the system to communicate with an Alarm Receiving Centre (not fitted on Optima Compact Gen4). New LED KeypadThe LED remote keypad operates with the Accenta and Optima Gen4 intruder systems. Up to four LED or LCD keypads can be connected to the system. Fire ZoneZones 7 and 8 may be programmed as a 24 Hour Fire Zone operating all of the time except during engineer mode. 250-event logThe last 250 events to have occurred are stored in the memory and can be displayed, with their date and time, on the LCD remote keypad screen. Duress CodeAllows the user to unset the system and silence the alarm under duress, using a second code that will communicate an alarm to an Alarm Receiving Centre. ChimeCan be used to select a low security chime alarm for various areas of your house, even when the main alarm is turned off. This is ideal for areas that require low level monitoring. Built-in tamper controlTo protect all wiring and detectors in the system from unauthorised access including the control panel and remote keypad covers. The Texecom Veritas 8 has the following outstanding features 8 Fully Programmable Zones Plus Tamper Single Button Quick Set Option Service Timers (Date Programmable) Latching Walk Test Model 2 Programmable Part Set Suites Soak Test Suite Texecom Bell Box Hold-off Mode Key Switch Facility Accepts Up To Six Backlit LED Remote Keypads PD6662:2010 Grade1 Class II Please NoteUnless Stated, our Alarm Panels are Not Supplied with a Back up Battery. If you require a battery then please select Also Available: CFA-0001 Veritas 8 This is the Veritas panel with keypad inbuilt into the panel.

    CFB-0001 Veritas 8 Compact A slimline version of the Veritas 8 with a smaller profile. CFC-0001 Veritas R8 A Veritas Panel with a seperate LED keypad. Category: Alarm Systems Condition: New Location: Walsall, United Kingdom Feedback: 9217 (100%) Brand: GardTec An Additional Remote Keypad for the Eurosec CP8L control panel. Please note that this keypad is not suitable for the CPX model. The 9941 keypad supplied (as pictured) uses a 4 or 6-digit PIN code to control system operation.If required you can also fit the 9943 keypad. This gives the user the option of employing an encrypted keyring proximity tag to simplify operation and minimise the chance of operator error.A 9651 panel can be connected to any speech dialler or plug-by digital communicator via its integral communications output socket. Its three fully programmable outputs further enhance system flexibility. Designed specifically to offer exceptional value for money.The 9448EUR-90 has been designed to meet the most professional alarm installation standards and yet it is easy to install, using simple but secure wiring. Category: Alarm Systems Condition: New Location: Bradford, United Kingdom Feedback: 42369 (99.7%) Brand: Texecom Toggle navigation Contact Us Save This Seller Postage Returns Payments TEXECOM VERITAS EXCEL 8 ZONE ALARM PANEL WITH LCD KEYPAD Product Information Details Introducing the Veritas Excel control panel from Texecom. Fully programmable and incorporating all the features that have made the Veritas R8 Plus the uncontested market leader. The Highly secure encrypted web browser for the I-On40 has a mobile and tablet friendly interface for easy on-site system configuration. If you are unsure please contact us prior to purchase. We will always go out of our way to source the product you are looking for. Contact Us The best way to contact us is through the eBay messaging system. Telephone Number: Shipping Information Items are dispatched within one working day of receiving cleared payment.

    If ordered before the daily cut-off, the item will be prepared and dispatched the same day. We offer the following postal services: We offer the following services depending on the weight and size of the parcel. Estimated delivery dates include seller's dispatch time, and will depend on postal service selected and receipt of cleared payment. Delivery times may vary, especially during peak periods Returns Policy If not satisfied with the item bought you can return it to us for a refund. Returns will not be accepted if tags are removed. All items are brand new and must be in the exact same condition as sent. We must be informed of return within 7 days of purchase, and the item must be returned within 14 days of purchase. The reason for return and your eBay ID number must be included with the item. All the refunds will be made excluding the actual postage charge. Payments Our preferred method of payment is via PayPal. Condition is New. Dispatched with Royal Mail 1st Class.Ideal for young, elderly or infirm. An additional PA facility exists on the remote keypads.Remote keypads for added flexibility Up to four slimline keypads can operate the system from any point in the property. New LCD Keypad - OptionalThe LCD remote keypad operates with the Optima Gen4 intruder systems.Up to four LCD keypads can be connected to the system. The large 2x16 characters with backlight display provide a full status indication and the keypad plays entry and exit tones. When a door is opened or a detector triggered in an area set to chime, the control panel will deliver a low-volume ?bing-bong? sound to alert you. This is ideal for areas that require low level monitoring. Zone names selectable from the libraryA new option accessible from the LCD remote keypad allows the installer to assign descriptors from a 22-name library to each of the eight zones.


  • Commentaires

    Aucun commentaire pour le moment

    Suivre le flux RSS des commentaires


    Ajouter un commentaire

    Nom / Pseudo :

    E-mail (facultatif) :

    Site Web (facultatif) :

    Commentaire :